ÍNDICE POR MARCAS
ÍNDICE POR ESPECIALIDAD
BUSCAR PRODUCTO
Features
Specifications

Cost-effective 12ch ECG

CardioCare 2000

The CardioCare is a 12 channel resting ECG which is the most economically priced without performance compromise, especially suitable for routine use in Private check, ER or Hospitals.

The design of CardioCare is maximized for the user's convenience (A4 size paper, one body type). One of special characteristics is the upgrade and option which makes it possible to be connected in various types of network system: Fax, PC(RS-232 port or LAN).

Productos Bionet


Specifications
ECG leads 12 leads simultaneous 10-second resting ECG
Dimension 296(W) x 305.5(H) x 92.5(D)mm, Approx. 2.98 kg
Recording channel 3,6,12 channel and 1 channel (60 sec)
Sensitivity 5,10,20, auto(I~aVF:10,V1~V6:5) mm/mV
Printing speed 12.5, 25, 50 mm/s
Filters AC(50/60 Hz, -20 dB or better)
Muscle (25 ~ 35 Hz, -3dB or better)
Base line drift (0.1 Hz, -3dB or better)
Low pass filter (off, 40 Hz, 100 Hz, 150 Hz)
Display
LCD display
LED indicator
2 x 16 character LCD Display
Sensitvity, speed, filter status, HR, printing form, rhythm lead
signal quality, power source, battery.
Keyboard Membrane keyboard, Alphanumeric and symbol available
Patient data
Basic measurement
ID, name, age, sex, height, weight
Heart rate, PR, QRS, QT/QTc, P-R-T axis
Recorder Thermal print head, Thermal roll paper
Report papers :
• width : A4 : 210mm or 8.5"
• length : A4 : 300mm or 11"
Effective writing width : 204 mm
Resolution :
• Vertical: 8 dots/mm
• Horizontal : 16dots/mm
Electrical Internal noise: 20uV (p-p) max
Input circuit: Floating input
Isolated and defibrillation protected
Input impedance: =10M Q
Input range: =±5mV
Common Mode Rejection: = +100dB
DC offset voltage: >±300mV
Time constant; 3.2sec
Patient leakage current: <10µA
Frequency response 0.05-150 Hz
Signal quality control Disconnected lead detection
Power Power supply: AC or built-in Battery(option)
Power requirement: 100 - 240 Vac, 50/60Hz, 1.0 - 0,5 A
Power consumption: 60W max
Battery capacity 1 hour of normal use(approximately 100 automatic ECG printouts)
Communication PC connection with RS-232 interface and LAN
Safety
Conformity
Class I, Type BF
CE,CSA
Environment Operating humidity: 30 ~ 85%
Operating Temperature: 10° ~ 40°C
Atmospheric pressure: 70 ~ 106 KPa
Standard accessory Power Cable 1ea, Patient Cable 1ea, Electrode 10ea, Chart Paper 1ea, Operation Manual 1ea
Options Rechargeable Battery(NI-MH), Cart, Hanger, Bag, PC s/w, Limb electrode, Chest electrode, RS-232C null cable, LAN cable(Ethernet-RJ-45)